This document contains guidance, material specifications, bills of quantitiy, technical design drawings, and step-by-step constuction photos for three large 45m3, 70m3 and 90m3 circular water reservoirs constructed from ferrocement.
Archives
Large Ferro-Cement Water Tank Design Parameters and Construction Details (UNHCR, 2006)
UNHCR Urine Diverting Dry Toilet (UDDT) Standard Operating Procedures
Double vault Urine Diversion Dry Toilets (UDDT) can be used as an alternative to pit latrines in refugee camps. They utilise two chambers for faeces, one of which is in use whilst the other is full and drying so that it can be safely disposed of after an appropriate period of time.
These Standard Operating Procedures (SOPs) were developed by Oxfam under UNHCR’s “Waste to Value” Project, which was funded by the Bill and Melinda Gates Foundation. They are largely based on UDDTs developed under the Waste to Value Project in Ethiopia.
- Tags: Excreta / Urine ReUse and Excreta Composting. Locations: Ethiopia. Organisations: Bill and Melinda Gates Foundation and OXFAM GB. DatabaseDocTypes: WASH Design Documentation. Categories: WASH Operational Guidelines.
F-402/2016a Drain Field Sizing Spreadsheet (UNHCR, 2016)
This sizing calculation tool has been designed to assist UNHCR and WASH actors correctly size drain fields for septic tanks in displaced settings taking into account numbers of users, soil type, and wastewater and sewage flows.
- Tags: Drain Fields and Drainage.
F-401/2016a Septic Tank Sizing Spreadsheet (UNHCR, 2016)
This sizing calculation tool has been designed to assist UNHCR and WASH actors correctly size septic tanks in displaced settings taking into account numbers of users, wastewater and sewage flows, sludge and scum accumulation rates, desludging periods, liquid retention times, and average annual ambient temperatures.
- Tags: Grey Water Disposal, Grey Water Disposal, Septic Tanks, and Septic Tanks. Categories: WASH Blank Forms and WASH Blank Forms.
DG-400 Design Guidelines for Toilets in Refugee Settings (UNHCR, 2015)
This document contains guidelines for toilets in refugee settings including: site selection; prevention of surface or ground water contamination; pit reinforcement; toilet slab strength; toilet slab anchorage; sanitary sealing; use of plastic sheeting; toilet doors; privacy walls; vector control measures; rain and stormwater protection; wash block accessories; collection of anal cleansing and sanitary materials; material specifications; handwashing stations design considerations; and environmental considerations for sourcing wood .
DG-300 Design Guidelines for Piped Water Networks in Refugee Settings (UNHCR, 2015)
This document contains guidelines to help UNHCR and WASH actors design piped water networks in refugee settings. It describes the minimum documentation that should be included for a water network design project.
- Tags: Piped Water Networks, WASH Monitoring, WASH Programme Management, WASH Programme Management, WASH Strategy Development, WASH Strategy Development, Water Pumping, Water Storage, Water Storage, Water Supply, and Water Supply. Languages: English, English, English, English, English, and English. Organisations: UNHCR, UNHCR, UNHCR, UNHCR, UNHCR, and UNHCR. Categories: WASH Guidelines, WASH Guidelines, WASH Guidelines, WASH Policy Guidelines, WASH Policy Guidelines, WASH Reference Documents, WASH Reference Documents, WASH Reference Documents, WASH Reference Documents, WASH Reference Documents, WASH Reference Documents, WASH Technical Designs, WASH Technical Designs, WASH Technical Designs, and WASH Technical Designs.