Archives

D-404/2015a Household Pour Flush Toilet and Bathing Unit (Septic Tank, Drain Field) Design and BoQ (UNHCR, 2015)

D404 Thumb2

This document contains materials to help UNHCR and WASH actors build post emergency household pour flush toilet and bathing units with septic tanks and drain fields in refugee settings.

D-408/2015a Post Emergency Pour Flush Institutional Latrine (Septic Tanks and Drainfield) Design and BoQ

D408 Thumb1

This document contains documentation to help UNHCR and WASH actors build pour flush institutional latrines in refugee settings with septic tanks and drain fields. The package includes: Technical Drawings; Step by Step Construction Drawings; Bills of Quantity; Material and Workmanship Specifications; and Design Calculations.

F-402/2016a Drain Field Sizing Spreadsheet (UNHCR, 2016)

F43 - Drain Field Thumb

This sizing calculation tool has been designed to assist UNHCR and WASH actors correctly size drain fields for septic tanks in displaced settings taking into account numbers of users, soil type, and wastewater and sewage flows.

F-401/2016a Septic Tank Sizing Spreadsheet (UNHCR, 2016)

F41 Septic Tank Sizing Calculator Thumb

This sizing calculation tool has been designed to assist UNHCR and WASH actors correctly size septic tanks in displaced settings taking into account numbers of users, wastewater and sewage flows, sludge and scum accumulation rates, desludging periods, liquid retention times, and average annual ambient temperatures.